{"id":21866,"date":"2026-10-02T04:15:10","date_gmt":"2026-10-02T04:15:10","guid":{"rendered":"https:\/\/tradefoxapps.sitepreview.me\/?p=21866"},"modified":"2026-11-06T23:03:29","modified_gmt":"2026-11-06T23:03:29","slug":"r1-r2-test","status":"publish","type":"post","link":"https:\/\/tradefoxapps.sitepreview.me\/fr\/r1-r2-test\/","title":{"rendered":"R1 R2 Test Explained: What the Reading Tells an Electrician"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"21866\" class=\"elementor elementor-21866\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bd69d62 e-flex e-con-boxed e-con e-parent\" data-id=\"bd69d62\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cfb4151 elementor-widget elementor-widget-text-editor\" data-id=\"cfb4151\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">The R1 R2 test is one of the most informative measurements taken during the dead testing sequence of an electrical installation. It confirms the continuity of protective conductors and gives the electrician the data needed to verify circuit integrity, calculate earth fault loop impedance, and satisfy the requirements of BS 7671:2018+A4:2026. For working electricians and apprentices building towards competence, understanding what the reading actually tells you matters far more than simply recording a number on a schedule of test results.<\/span><\/p><p><span style=\"font-weight: 400;\">This guide breaks down the purpose of the test, the method, the expected values, and how to interpret results correctly and safely. <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6eab675 e-flex e-con-boxed e-con e-parent\" data-id=\"6eab675\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7909096 elementor-widget elementor-widget-heading\" data-id=\"7909096\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What R1 and R2 Actually Measure\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ed770f elementor-widget elementor-widget-text-editor\" data-id=\"6ed770f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">This is a continuity test carried out on a final circuit while it is dead. The two values represent specific conductors:<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-709890a elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"709890a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>R1: <\/b>The resistance of the line (phase) conductor.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>R2: <\/b>The resistance of the circuit protective conductor (CPC), usually the earth conductor.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-190a831 elementor-widget elementor-widget-text-editor\" data-id=\"190a831\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Measured together, R1 + R2 gives the total resistance of the line conductor and the CPC from the origin of the circuit to the furthest point. This combined figure confirms that the protective conductor is continuous and correctly connected throughout the circuit.<\/span><\/p><p><span style=\"font-weight: 400;\">Continuity of protective conductors is a mandatory dead test under Regulation 643.2.1 of BS 7671, carried out during initial verification and every periodic inspection.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64d4f4d elementor-widget elementor-widget-heading\" data-id=\"64d4f4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">R1 R2 Test Versus the R2-Only Test\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7499404 elementor-widget elementor-widget-text-editor\" data-id=\"7499404\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Apprentices often confuse two related checks, so it is worth separating them clearly:<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-adadf07 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"adadf07\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>R1 + R2:<\/b> The line conductor and CPC are linked at the board, and the reading gives their combined resistance. This feeds directly into your Zs calculation.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>R2 only:<\/b> Measured on its own, usually with a wander lead from the main earthing terminal to the CPC at each point. This confirms CPC continuity where you do not need the line contribution, such as testing bonding or a separate protective conductor.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d949b8a elementor-widget elementor-widget-text-editor\" data-id=\"d949b8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Both prove the CPC is sound. The difference is whether you also capture the line conductor for the loop impedance sum.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7143260 e-flex e-con-boxed e-con e-parent\" data-id=\"7143260\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8ac8003 elementor-widget elementor-widget-heading\" data-id=\"8ac8003\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Why the Test Matters\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c81fbc5 elementor-widget elementor-widget-text-editor\" data-id=\"c81fbc5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">The primary purpose is to confirm the continuity of protective conductors, which underpins automatic disconnection of supply under fault conditions. If the CPC is broken, high in resistance, or incorrectly terminated, the protective device may not operate within the required disconnection time, leaving exposed conductive parts dangerous during a fault.<\/span><\/p><p><span style=\"font-weight: 400;\">The reading also feeds directly into loop impedance verification. The measured R1 + R2 value is used to establish the earth fault loop impedance (Zs) for the circuit:<\/span><\/p><p><b>Zs = Ze + (R1 + R2)<\/b><\/p><p><span style=\"font-weight: 400;\">Here, Ze is the external earth fault loop impedance measured at the origin. By adding the measured R1 + R2 to Ze, the electrician can calculate the expected Zs without carrying out a live loop test at every point. That is useful where live testing is impractical or where RCD nuisance tripping would interfere.<\/span><\/p><p><span style=\"font-weight: 400;\">The calculated Zs is then compared against the maximum permitted values in BS 7671 Tables 41.2 to 41.5 for the relevant protective device type and rating. If the calculated figure exceeds the maximum, disconnection times cannot be guaranteed and the circuit does not comply. <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4278b1 e-flex e-con-boxed e-con e-parent\" data-id=\"d4278b1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-65797f0 elementor-widget elementor-widget-heading\" data-id=\"65797f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Safe Isolation Comes First\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef3d74d elementor-widget elementor-widget-image\" data-id=\"ef3d74d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"825\" height=\"550\" src=\"https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/Safe-Isolation-Comes-First.png\" class=\"attachment-large size-large wp-image-21876\" alt=\"Safe Isolation Comes First\" srcset=\"https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/Safe-Isolation-Comes-First.png 825w, https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/Safe-Isolation-Comes-First-300x200.png 300w, https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/Safe-Isolation-Comes-First-768x512.png 768w, https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/Safe-Isolation-Comes-First-18x12.png 18w, https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/Safe-Isolation-Comes-First-600x400.png 600w\" sizes=\"(max-width: 825px) 100vw, 825px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41d0086 elementor-widget elementor-widget-text-editor\" data-id=\"41d0086\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">No <a href=\"https:\/\/tradefoxapps.sitepreview.me\/fr\/continuity-testing-on-circuits-step-by-step-with-gs38-compliant-probes\/\">continuity testing<\/a> takes place on a live circuit. Before any measurement:<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5872135 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"5872135\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Isolate the circuit: <\/b><a href=\"https:\/\/penfault.com\/correct-isolation-procedure\/\">Secure the isolation<\/a> so it cannot be inadvertently re-energised, and lock off where possible.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Prove dead correctly: <\/b>Use an approved voltage indicator to GS38, verified against a proving unit before and after the check. Probes should have finger guards and no more than 4mm of exposed metal at the tips, preferably 2mm.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Null your leads: <\/b>Zero the test leads on the low ohms range before testing, or lead resistance will inflate every reading.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32776c2 elementor-widget elementor-widget-text-editor\" data-id=\"32776c2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Failing to account for lead resistance can push a marginal circuit into apparent non-compliance, or mask a genuine fault. Getting isolation and nulling right is what makes the rest of the test trustworthy. <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bdcce4d e-flex e-con-boxed e-con e-parent\" data-id=\"bdcce4d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-389eca5 elementor-widget elementor-widget-heading\" data-id=\"389eca5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How the Test Is Carried Out\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e047eb0 elementor-widget elementor-widget-text-editor\" data-id=\"e047eb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">There are two recognised methods for a standard <a href=\"https:\/\/tradefoxapps.sitepreview.me\/fr\/ring-vs-radial-circuits-in-uk-homes-pros-cons-when-to-choose\/\">radial circuit<\/a>, and the choice depends on the circuit and site conditions.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-329bf78 elementor-widget elementor-widget-heading\" data-id=\"329bf78\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Method 1: The Wander Lead Approach\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-99d9d64 elementor-widget elementor-widget-text-editor\" data-id=\"99d9d64\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">A temporary link connects the line conductor to the CPC at the distribution board. The electrician then measures the resistance between line and earth at each point on the circuit, such as socket outlets, lighting points, and switches. The reading at the furthest point gives the full R1 + R2 value.<\/span><\/p><p><span style=\"font-weight: 400;\">This method confirms continuity and correct polarity at every accessory tested, which makes it thorough and well suited to verifying a new installation.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9319a9b elementor-widget elementor-widget-heading\" data-id=\"9319a9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Method 2: The Cross-Connect Method\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f10096 elementor-widget elementor-widget-text-editor\" data-id=\"1f10096\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">The line and CPC are linked together at the distribution board, and readings are taken across the two conductors. This approach is efficient but assumes <a href=\"https:\/\/tradefoxapps.sitepreview.me\/fr\/cable-termination\/\">terminations<\/a> are sound throughout, so it is often paired with additional checks.<\/span><\/p><p><span style=\"font-weight: 400;\">Whichever method you use, remove the temporary link and reinstate the circuit correctly before energising. Leaving a link in place is a serious error.\u00a0 \u00a0 <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ae6fa6 elementor-widget elementor-widget-heading\" data-id=\"1ae6fa6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ring Final Circuits Are Different\n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7e8bfb8 elementor-widget elementor-widget-text-editor\" data-id=\"7e8bfb8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">A ring final circuit is not tested the same way as a radial, and this trips up a lot of people. Regulation 643.2.1 requires an extra step because you have to prove the ring is actually a ring:<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ca0420b elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"ca0420b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Premi\u00e8re \u00e9tape : <\/b>Identify both legs at the consumer unit and measure the end-to-end resistance of each conductor in turn, giving r1 (line), rn (neutral), and r2 (CPC).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Deuxi\u00e8me \u00e9tape : <\/b>Cross-connect the conductors and take readings at each socket outlet.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d43f817 elementor-widget elementor-widget-text-editor\" data-id=\"d43f817\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Done correctly, the R1 + R2 value should read roughly the same at every outlet, at approximately (r1 + r2) divided by 4. A reading that climbs at one point suggests an interconnection, a break in the ring, or a spur mistaken for part of the ring.\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a340c2a e-flex e-con-boxed e-con e-parent\" data-id=\"a340c2a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3125ee1 elementor-widget elementor-widget-heading\" data-id=\"3125ee1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Understanding the Reading\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d8d586c elementor-widget elementor-widget-text-editor\" data-id=\"d8d586c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">A number on its own means little without something to compare it against. There is no single pass or fail figure.<\/span><\/p><p><span style=\"font-weight: 400;\">For any circuit, the expected R1 + R2 can be calculated from the conductor cross-sectional areas, the cable length, and the resistance per metre of the conductors. Published reference values for copper conductors let you predict a target figure, and a measured value close to that target indicates sound, continuous conductors.<\/span><\/p><p><span style=\"font-weight: 400;\">Consider what different readings suggest:<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e2ec18b elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"e2ec18b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Close to the calculated value:<\/b> Good continuity and correct conductor sizing.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Significantly higher:<\/b> A high resistance joint, a loose termination, corrosion, or a damaged conductor.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Open or infinite:<\/b> A break in continuity, a missing link, or a disconnected conductor.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Far lower than expected: <\/b>A parallel path, such as the CPC touching other earthed metalwork, which can disguise a genuine continuity problem.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ccd7170 elementor-widget elementor-widget-text-editor\" data-id=\"ccd7170\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Temperature affects conductor resistance too. Readings taken cold differ from those at working temperature, so the R1 + R2 value is corrected for temperature before it is added to Ze for the Zs calculation. Guidance material such as IET Guidance Note 3 sets out the correction factors used.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e698689 e-flex e-con-boxed e-con e-parent\" data-id=\"e698689\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-242f456 elementor-widget elementor-widget-heading\" data-id=\"242f456\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Common Errors and How to Avoid Them\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a927018 elementor-widget elementor-widget-text-editor\" data-id=\"a927018\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">A few recurring mistakes undermine the reliability of the result:<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-40f09ad elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"40f09ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Skipping the null: <\/b>The most frequent error, adding a small but meaningful resistance to every reading.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Testing before proving dead: <\/b>A serious safety failure that must never happen.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Poor probe contact: <\/b>Painted or corroded terminals produce inflated readings mistaken for faults.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-long-arrow-alt-right\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M313.941 216H12c-6.627 0-12 5.373-12 12v56c0 6.627 5.373 12 12 12h301.941v46.059c0 21.382 25.851 32.09 40.971 16.971l86.059-86.059c9.373-9.373 9.373-24.569 0-33.941l-86.059-86.059c-15.119-15.119-40.971-4.411-40.971 16.971V216z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Parallel earth paths:<\/b> Extensive bonding or metallic containment can give artificially low readings that hide a broken CPC.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4e6c220 elementor-widget elementor-widget-text-editor\" data-id=\"4e6c220\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">A disciplined routine of isolate, prove dead, null the instrument, test methodically, and cross-check against calculated values will catch most of these.\u00a0<\/span><\/p><p><span style=\"font-weight: 400;\">Understanding the R1 R2 test takes practice as well as technical knowledge. <\/span><strong><a href=\"https:\/\/learn.tradefoxapp.com\/\">Tradefox<\/a><\/strong><span style=\"font-weight: 400;\"> offers practical electrical simulations that let you revisit key skills and build confidence at your own pace. \u00a0 \u00a0 <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1b051 elementor-widget elementor-widget-image\" data-id=\"2c1b051\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"825\" height=\"550\" src=\"https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/Parallel-earth-paths.png\" class=\"attachment-large size-large wp-image-21889\" alt=\"Parallel earth paths\" srcset=\"https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/Parallel-earth-paths.png 825w, https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/Parallel-earth-paths-300x200.png 300w, https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/Parallel-earth-paths-768x512.png 768w, https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/Parallel-earth-paths-18x12.png 18w, https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/Parallel-earth-paths-600x400.png 600w\" sizes=\"(max-width: 825px) 100vw, 825px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-da9d0a6 e-flex e-con-boxed e-con e-parent\" data-id=\"da9d0a6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fe98b52 elementor-widget elementor-widget-heading\" data-id=\"fe98b52\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Recording and Compliance\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edbf771 elementor-widget elementor-widget-text-editor\" data-id=\"edbf771\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">The R1 + R2 values, along with the derived Zs, are recorded on the schedule of test results that accompanies an Electrical Installation Certificate, Minor Electrical Installation Works Certificate, or Electrical Installation Condition Report. Accurate recording is a professional requirement, and the figures form part of the evidence that the installation meets the standard. Note that the model forms were updated under Amendment 4, so always work to the current schedule.<\/span><\/p><p><span style=\"font-weight: 400;\">For anyone working towards inspection and testing qualifications, competence here is a core assessed skill. It is a genuine safety verification, not a box-ticking exercise. \u00a0 <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d18d314 elementor-widget elementor-widget-text-editor\" data-id=\"d18d314\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"tf-sim\"><div class=\"tf-sim-t\"><p class=\"tf-sim-k\">Practise this in a simulation<\/p><p class=\"tf-sim-p\">Practise R1+R2 continuity testing on virtual circuits before you do it for real.<\/p><\/div><a class=\"tf-sim-btn\" href=\"https:\/\/tradefoxapps.sitepreview.me\/fr\/electric-courses\/\">Try the Electrician course<\/a><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a495b37 e-flex e-con-boxed e-con e-parent\" data-id=\"a495b37\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-57beb72 elementor-widget elementor-widget-heading\" data-id=\"57beb72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Key Takeaways\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-726d292 elementor-widget elementor-widget-text-editor\" data-id=\"726d292\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">The R1 R2 test verifies the continuity of the line conductor and protective conductor across a final circuit, confirms the CPC is sound, and provides the R1 + R2 value used to calculate earth fault loop impedance. Carried out dead, proved dead to <a href=\"https:\/\/tradefoxapps.sitepreview.me\/fr\/guide-to-gs38-what-they-are-and-how-to-stay-compliant\/\">GS38<\/a>, nulled correctly, and interpreted against a calculated expected value and the BS 7671 maximum Zs tables, it gives clear evidence of circuit integrity and compliance. Read properly, the number is not just a figure on a certificate. It is confirmation that the safety of the installation can be relied upon.\u00a0 <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>The R1 R2 test is one of the most informative measurements taken during the dead testing sequence of an electrical installation. It confirms the continuity of protective conductors and gives the electrician the data needed to verify circuit integrity, calculate earth fault loop impedance, and satisfy the requirements of BS 7671:2018+A4:2026. For working electricians and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":21868,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_glsr_average":0,"_glsr_ranking":0,"_glsr_reviews":0,"footnotes":""},"categories":[1],"tags":[272,1198,2233,2239,1426,2235,2243,2242,1422,2236,2234,1834,2240,1330,1251,2241,2238,2237],"class_list":["post-21866","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical","tag-bs-7671","tag-continuity-test","tag-continuity-testing","tag-cpc-continuity","tag-dead-test","tag-earth-fault-loop","tag-eicr-test","tag-electrical-testing","tag-insulation-resistance","tag-loop-impedance","tag-protective-conductor","tag-prove-dead","tag-ring-circuit","tag-ring-final","tag-safe-isolation","tag-wander-lead","tag-ze-value","tag-zs-value"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>R1 R2 Test Explained: What the Reading Tells an Electrician<\/title>\n<meta name=\"description\" content=\"Learn what an R1 R2 test measures, how to carry it out safely, interpret readings, spot faults, and use the result to verify circuit integrity.\" \/>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"R1 R2 Test Explained: What the Reading Tells an Electrician\" \/>\n<meta property=\"og:description\" content=\"Learn what an R1 R2 test measures, how to carry it out safely, interpret readings, spot faults, and use the result to verify circuit integrity.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tradefoxapps.sitepreview.me\/fr\/r1-r2-test\/\" \/>\n<meta property=\"og:site_name\" content=\"Tradefox | Construction Training Online\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61561067514381\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-02T04:15:10+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-06T23:03:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/R1-R2-Test-Explained.png\" \/>\n\t<meta property=\"og:image:width\" content=\"825\" \/>\n\t<meta property=\"og:image:height\" content=\"550\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Tradefoxapp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Tradefox_app\" \/>\n<meta name=\"twitter:site\" content=\"@Tradefox_app\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tradefoxapp\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/r1-r2-test\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/r1-r2-test\\\/\"},\"author\":{\"name\":\"Tradefoxapp\",\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/#\\\/schema\\\/person\\\/dabb246cab9c457abaa00d85cb523154\"},\"headline\":\"R1 R2 Test Explained: What the Reading Tells an Electrician\",\"datePublished\":\"2026-10-02T04:15:10+00:00\",\"dateModified\":\"2026-11-06T23:03:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/r1-r2-test\\\/\"},\"wordCount\":1437,\"publisher\":{\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/r1-r2-test\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/R1-R2-Test-Explained.png\",\"keywords\":[\"bs 7671\",\"continuity test\",\"continuity testing\",\"cpc continuity\",\"dead test\",\"earth fault loop\",\"eicr test\",\"electrical testing\",\"insulation resistance\",\"loop impedance\",\"protective conductor\",\"prove dead\",\"ring circuit\",\"Ring final\",\"safe isolation\",\"wander lead\",\"ze value\",\"zs value\"],\"articleSection\":[\"Electrical\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/r1-r2-test\\\/\",\"url\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/r1-r2-test\\\/\",\"name\":\"R1 R2 Test Explained: What the Reading Tells an Electrician\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/r1-r2-test\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/r1-r2-test\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/R1-R2-Test-Explained.png\",\"datePublished\":\"2026-10-02T04:15:10+00:00\",\"dateModified\":\"2026-11-06T23:03:29+00:00\",\"description\":\"Learn what an R1 R2 test measures, how to carry it out safely, interpret readings, spot faults, and use the result to verify circuit integrity.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/r1-r2-test\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/r1-r2-test\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/r1-r2-test\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/R1-R2-Test-Explained.png\",\"contentUrl\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/R1-R2-Test-Explained.png\",\"width\":825,\"height\":550,\"caption\":\"R1 R2 Test Explained\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/r1-r2-test\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"R1 R2 Test Explained: What the Reading Tells an Electrician\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/#website\",\"url\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/\",\"name\":\"Tradefox | Construction Training Online\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/#organization\",\"name\":\"Tradefox | Construction Training Online\",\"url\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/logo.jpg\",\"contentUrl\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/logo.jpg\",\"width\":1024,\"height\":208,\"caption\":\"Tradefox | Construction Training Online\"},\"image\":{\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=61561067514381\",\"https:\\\/\\\/x.com\\\/Tradefox_app\",\"https:\\\/\\\/www.instagram.com\\\/tradefoxapp\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/tradefox-ltd\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tradefoxapps.sitepreview.me\\\/#\\\/schema\\\/person\\\/dabb246cab9c457abaa00d85cb523154\",\"name\":\"Tradefoxapp\",\"sameAs\":[\"https:\\\/\\\/tradefoxapps.sitepreview.me\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"R1 R2 Test Explained: What the Reading Tells an Electrician","description":"Learn what an R1 R2 test measures, how to carry it out safely, interpret readings, spot faults, and use the result to verify circuit integrity.","robots":{"index":"noindex","follow":"follow"},"og_locale":"fr_FR","og_type":"article","og_title":"R1 R2 Test Explained: What the Reading Tells an Electrician","og_description":"Learn what an R1 R2 test measures, how to carry it out safely, interpret readings, spot faults, and use the result to verify circuit integrity.","og_url":"https:\/\/tradefoxapps.sitepreview.me\/fr\/r1-r2-test\/","og_site_name":"Tradefox | Construction Training Online","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61561067514381","article_published_time":"2026-10-02T04:15:10+00:00","article_modified_time":"2026-11-06T23:03:29+00:00","og_image":[{"width":825,"height":550,"url":"https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/R1-R2-Test-Explained.png","type":"image\/png"}],"author":"Tradefoxapp","twitter_card":"summary_large_image","twitter_creator":"@Tradefox_app","twitter_site":"@Tradefox_app","twitter_misc":{"\u00c9crit par":"Tradefoxapp","Dur\u00e9e de lecture estim\u00e9e":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tradefoxapps.sitepreview.me\/r1-r2-test\/#article","isPartOf":{"@id":"https:\/\/tradefoxapps.sitepreview.me\/r1-r2-test\/"},"author":{"name":"Tradefoxapp","@id":"https:\/\/tradefoxapps.sitepreview.me\/#\/schema\/person\/dabb246cab9c457abaa00d85cb523154"},"headline":"R1 R2 Test Explained: What the Reading Tells an Electrician","datePublished":"2026-10-02T04:15:10+00:00","dateModified":"2026-11-06T23:03:29+00:00","mainEntityOfPage":{"@id":"https:\/\/tradefoxapps.sitepreview.me\/r1-r2-test\/"},"wordCount":1437,"publisher":{"@id":"https:\/\/tradefoxapps.sitepreview.me\/#organization"},"image":{"@id":"https:\/\/tradefoxapps.sitepreview.me\/r1-r2-test\/#primaryimage"},"thumbnailUrl":"https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/R1-R2-Test-Explained.png","keywords":["bs 7671","continuity test","continuity testing","cpc continuity","dead test","earth fault loop","eicr test","electrical testing","insulation resistance","loop impedance","protective conductor","prove dead","ring circuit","Ring final","safe isolation","wander lead","ze value","zs value"],"articleSection":["Electrical"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/tradefoxapps.sitepreview.me\/r1-r2-test\/","url":"https:\/\/tradefoxapps.sitepreview.me\/r1-r2-test\/","name":"R1 R2 Test Explained: What the Reading Tells an Electrician","isPartOf":{"@id":"https:\/\/tradefoxapps.sitepreview.me\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tradefoxapps.sitepreview.me\/r1-r2-test\/#primaryimage"},"image":{"@id":"https:\/\/tradefoxapps.sitepreview.me\/r1-r2-test\/#primaryimage"},"thumbnailUrl":"https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/R1-R2-Test-Explained.png","datePublished":"2026-10-02T04:15:10+00:00","dateModified":"2026-11-06T23:03:29+00:00","description":"Learn what an R1 R2 test measures, how to carry it out safely, interpret readings, spot faults, and use the result to verify circuit integrity.","breadcrumb":{"@id":"https:\/\/tradefoxapps.sitepreview.me\/r1-r2-test\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tradefoxapps.sitepreview.me\/r1-r2-test\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/tradefoxapps.sitepreview.me\/r1-r2-test\/#primaryimage","url":"https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/R1-R2-Test-Explained.png","contentUrl":"https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2026\/10\/R1-R2-Test-Explained.png","width":825,"height":550,"caption":"R1 R2 Test Explained"},{"@type":"BreadcrumbList","@id":"https:\/\/tradefoxapps.sitepreview.me\/r1-r2-test\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/tradefoxapps.sitepreview.me\/"},{"@type":"ListItem","position":2,"name":"R1 R2 Test Explained: What the Reading Tells an Electrician"}]},{"@type":"WebSite","@id":"https:\/\/tradefoxapps.sitepreview.me\/#website","url":"https:\/\/tradefoxapps.sitepreview.me\/","name":"Tradefox | Formation en construction en ligne","description":"","publisher":{"@id":"https:\/\/tradefoxapps.sitepreview.me\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tradefoxapps.sitepreview.me\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/tradefoxapps.sitepreview.me\/#organization","name":"Tradefox | Formation en construction en ligne","url":"https:\/\/tradefoxapps.sitepreview.me\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/tradefoxapps.sitepreview.me\/#\/schema\/logo\/image\/","url":"https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2024\/03\/logo.jpg","contentUrl":"https:\/\/tradefoxapps.sitepreview.me\/wp-content\/uploads\/2024\/03\/logo.jpg","width":1024,"height":208,"caption":"Tradefox | Construction Training Online"},"image":{"@id":"https:\/\/tradefoxapps.sitepreview.me\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=61561067514381","https:\/\/x.com\/Tradefox_app","https:\/\/www.instagram.com\/tradefoxapp\/","https:\/\/www.linkedin.com\/company\/tradefox-ltd\/"]},{"@type":"Person","@id":"https:\/\/tradefoxapps.sitepreview.me\/#\/schema\/person\/dabb246cab9c457abaa00d85cb523154","name":"Tradefoxapp","sameAs":["https:\/\/tradefoxapps.sitepreview.me"]}]}},"_links":{"self":[{"href":"https:\/\/tradefoxapps.sitepreview.me\/fr\/wp-json\/wp\/v2\/posts\/21866","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tradefoxapps.sitepreview.me\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tradefoxapps.sitepreview.me\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tradefoxapps.sitepreview.me\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tradefoxapps.sitepreview.me\/fr\/wp-json\/wp\/v2\/comments?post=21866"}],"version-history":[{"count":37,"href":"https:\/\/tradefoxapps.sitepreview.me\/fr\/wp-json\/wp\/v2\/posts\/21866\/revisions"}],"predecessor-version":[{"id":25926,"href":"https:\/\/tradefoxapps.sitepreview.me\/fr\/wp-json\/wp\/v2\/posts\/21866\/revisions\/25926"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tradefoxapps.sitepreview.me\/fr\/wp-json\/wp\/v2\/media\/21868"}],"wp:attachment":[{"href":"https:\/\/tradefoxapps.sitepreview.me\/fr\/wp-json\/wp\/v2\/media?parent=21866"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tradefoxapps.sitepreview.me\/fr\/wp-json\/wp\/v2\/categories?post=21866"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tradefoxapps.sitepreview.me\/fr\/wp-json\/wp\/v2\/tags?post=21866"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}